1

Belser UC, Grütter L, Vailati F, Bornstein MM, Weber HP, Buser D. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: a cross-sectional, retrospective study in 45 patients with a 2- to 4-year follow-up using pink and white esthetic scores. J Periodontol 2009;80:140-51.

10.1902/jop.2009.080435
2

Buzayan MM, Yunus NB. Passive fit in screw retained multi-unit implant prosthesis understanding and achieving: a review of the literature. J Indian Prosthodont Soc 2014;14:16-23.

10.1007/s13191-013-0343-x24604993PMC3935037
3

Rutkūnas V, Gečiauskaitė A, Jegelevičius D, Vaitiekūnas M. Accuracy of digital implant impressions with intraoral scanners: a systematic review. Eur J Oral Implantol 2017;10:101-20.

28944372
4

Revilla-León M, Lanis A, Yilmaz B, Kois JC, Gallucci GO. Intraoral digital implant scans: parameters to improve accuracy. J Prosthodont 2023;32:150-64.

10.1111/jopr.13749
5

Park J, Lim YJ, Kim MJ, Kwon HB. Complete mouth rehabilitation through integration of multi-source digital information: a case report. J Implantol Appl Sci 2023;27:141-9.

10.32542/implantology.2023016
6

Amin S, Weber HP, Finkelman M, El Rafie K, Kudara Y, Papaspyridakos P. Digital vs. conventional full-arch implant impressions: a comparative study. Clin Oral Implants Res 2017;28:1360-7.

10.1111/clr.12994
7

Kim GH, Park EJ, Cho YE. A comparison of scan data accuracy of implant scan body and encoded healing abutment. J Implantol Appl Sci 2024;28:32-41.

10.32542/implantology.2024004
8

Mohajerani R, Djalalinia S, Alikhasi M. The effects of scan body geometry on the precision and the trueness of implant impressions using intraoral scanners: a systematic review. Dent J (Basel) 2025;13:252.

10.3390/dj1306025240559155PMC12191632
9

Wu HK, Chen G, Huang X, Deng F, Li Y. Accuracy of single-implant digital impression with various scanbody exposure levels at anterior and posterior regions. J Dent 2023;138:104641.

10.1016/j.jdent.2023.104641
10

Petchmedyai P, Thanasrisuebwong P. Optimizing digital implant impressions: evaluating the significance of scan body image deficiency and alignment under varied scan body exposures. PLoS One 2023;18:e0291831.

10.1371/journal.pone.029183137733766PMC10513296
11

Mourouzis P. Critical methodological factors influencing the accuracy of intraoral scanners in digital dentistry research. Comput Biol Med 2025;187:109780.

10.1016/j.compbiomed.2025.109780
12

Ruggiero G, Sorrentino R, Ficuciello F, Lo Russo L, Esperouz F, Zarone F. A centripetally rotating implant scan body concept for complete-arch scanning: an in vitro study. J Dent 2026;169:106623.

10.1016/j.jdent.2026.106623
13

Moradi S, Laurendeau D, Gosselin C. Multiple cylinder extraction from organized point clouds. Sensors (Basel) 2021;21:7630.

10.3390/s2122763034833706PMC8621001
14

Pan Y, Tsoi JKH, Lam WYH, Pow EHN. Implant framework misfit: a systematic review on assessment methods and clinical complications. Clin Implant Dent Relat Res 2021;23:244-58.

10.1111/cid.12968
15

Jeong B, Lee Y, Hong SJ, Paek J, Noh K, Pae A, et al. Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height. J Korean Acad Prosthodont 2021;59:27-35.

10.4047/jkap.2021.59.1.27
16

Choi YD, Lee KE, Mai HN, Lee DH. Effects of scan body exposure and operator on the accuracy of image matching of implant impressions with scan bodies. J Prosthet Dent 2020;124:379.e1-6.

10.1016/j.prosdent.2020.04.004
17

Gómez-Polo M, Sallorenzo A, Ortega R, Gómez-Polo C, Barmak AB, Att W, et al. Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scans. J Prosthet Dent 2024;131:119-27.

10.1016/j.prosdent.2021.11.018
18

Nam NE, Shin SH, Lim JH, Lee B, Shim JS, Kim JE. Accuracy of implant position reproduction according to exposed length of the scan body during optical scanning: an in vitro study. Appl Sci 2021;11:1689.

10.3390/app11041689
19

Lee JH, Jo JS, Lee SY. Digital impression accuracy for bone-level and tissue-level implants using scan bodies of different heights. Sci Rep 2025;15:37367.

10.1038/s41598-025-20524-641145637PMC12559281
20

Sicilia E, Lagreca G, Papaspyridakos P, Finkelman M, Cobo J, Att W, et al. Effect of supramucosal height of a scan body and implant angulation on the accuracy of intraoral scanning: an in vitro study. J Prosthet Dent 2024;131:1126-34.

10.1016/j.prosdent.2023.01.018
Information
  • Publisher :The Korean Academy of Oral & Maxillofacial Implantology
  • Publisher(Ko) :대한구강악안면임플란트학회
  • Journal Title :Journal of implantology and applied sciences
  • Journal Title(Ko) :대한구강악안면임플란트학회지
  • Volume : 30
  • No :2
  • Pages :86-97
  • Received Date : 2026-06-01
  • Revised Date : 2026-06-24
  • Accepted Date : 2026-06-27