All Issue

2017 Vol.21, Issue 2 Preview Page
June 2017. pp. 110-127
Abstract
References
1
Suzuki S, Kobayashi H, Ogawa T. Implant stability change and osseointegration speed of immediately loaded photofunctionalized implants. Implant Dentistry. 2013; 22: 481-490.
10.1097/ID.0b013e31829deb6224021973
2
Funato A, Ogawa T. Photofunctionalized dental implants: a case series in compromised bone. Int J Oral Maxillofac Implants. 2013; 28: 1589-1601.
10.11607/jomi.323224278928
3
Hirota M, Ozawa T, Iwai T, et al. Implants stability development of photofunctionalized implants placed in regular and complex cases: a case-control study. Int J Oral Maxillofac Implants. 2016; 31: 676-686.
10.11607/jomi.411527183088
4
Kitajima H, Ogawa T. The use of photofunctionalized implants for low or extremely low primary stability cases. Int J Oral Maxillofac Implants. 2016; 31: 439-447.
10.11607/jomi.405427004291
5
Ogawa T. Ultraviolet photofunctionalization of titanium implants. Int J Oral Maxillofac Implants. 2014; 29: e95-e102.
10.11607/jomi.te4724451893
6
Aita H, Hori N, Takeuchi M, et al. The effect of ultraviolet functionalization of titanium on integration with bone. Biomaterials. 2009; 30: 1015-1025.
10.1016/j.biomaterials.2008.11.00419042016
7
Iwasa F, Hori N, Ueno T, et al. Enhancement of osteoblast adhesion to UV-photofunctionalized titanium via an electrostatic mechanism. Biomaterials. 2010; 31: 2717-2727.
10.1016/j.biomaterials.2009.12.02420035996
8
Hori N, Ueno T, Minamikawa H, et al. Electrostatic control of protein adsorption on UV-photofunctionalized titanium. Acta Biomater. 2010; 6: 4175-4180.
10.1016/j.actbio.2010.05.00620466081
9
Hori N, Ueno T, Suzuki T, et al. Ultraviolet light treatment for the restoration of age-related degradation of titanium bioactivity. Int J Oral Maxillofac Implants. 2010; 25: 49-62.
20209187
10
Ueno T, Yamada M, Hori N, et al. Effect of ultraviolet photoactivation of titanium on osseointegration in a rat model. Int J Oral Maxillofac Implants. 2010; 25: 287-294.
20369086
11
Ueno T, Yamada M, Suzuki T, et al. Enhancement of bone-titanium integration profile with UVphotofunctionalized titanium in a gap healing model. Biomaterials. 2010; 31: 1546-1557.
10.1016/j.biomaterials.2009.11.01819962757
12
Pyo SW, Park YB, Moon HS, et al. Photofunctionalization enhances bone-implant contact, dynamics of interfacial osteogenesis, marginal bone seal, and removal torque value of implants: a dog jawbone study. Implant Dent. 2013; 22: 666-675.
10.1097/ID.000000000000000324185466
13
Morra M, Cassinelli C, Bruzzone G, et al. Surface chemistry effects of topographic modification of titanium dental implant surfaces: 1. Surface analysis. Int J Oral Maxillofac Implants. 2003; 18: 40-45.
12608667
14
Att W, Hori N, Iwasa F, et al. The effect of UV-photofunctionalization on the time-related bioactivity of titanium and chromium-cobalt alloys. Biomaterials. 2009; 30: 4268-4276.
10.1016/j.biomaterials.2009.04.04819473697
15
Yamada M, Miyauchi T, Yamamoto A, et al. Enhancement of adhesion strength and cellular stiffness of osteoblasts on mirror-polished titanium surface by UV-photofunctionalization. Acta Biomater. 2010; 6: 4578-4588.
10.1016/j.actbio.2010.07.01020633705
16
Miyauchi T, Yamada M, Yamamoto A, et al. The enhanced characteristics of osteoblast adhesion to photofunctionalized nanoscale TiO2 layers on biomaterials surfaces. Biomaterials. 2010; 31: 3827-3839.
10.1016/j.biomaterials.2010.01.13320153521
17
Terehyden H, Lang NP, Bierbaum S, et al. Osseointegration - communication of cells. Clin Oral Implants Res. 2012; 23: 1127-1135.
10.1111/j.1600-0501.2011.02327.x22092345
18
Raghavendra S, Wood MC, Taylor TD. Early wound healing around endosseous implants: a literature review. Int J Oral Maxillofac Implants. 2005; 20: 425-431.
15973954
19
Gomes JB, Campos FE, Marin C, et al. Implant biomechanical stability variation at early implantation times in vivo: an experimental study in dogs. Int J Oral Maxillofac Implants. 2013; 28: e128-e134.
10.11607/jomi.288523748331
20
Han J, Lulic M, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: II. Implant surface modifications and implant diameter. Clin Oral Implants Res. 2010; 21: 605-611.
10.1111/j.1600-0501.2009.01909.x20666787
21
Gupta RK, Padmanabhan TV. An evaluation of the resonance frequency analysis device: examiner reliability and repeatability of readings. J Oral Implantol. 2013; 39: 704-707.
10.1563/AAID-JOI-D-11-0009921970725
22
Nedir R, Bischof M, Szmukler-Moncler S, et al. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res. 2004; 15: 520-528.
10.1111/j.1600-0501.2004.01059.x15355393
23
Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996; 7: 261-267.
10.1034/j.1600-0501.1996.070308.x9151590
24
Huang HL, Tsai MT, Su KC, et al. Relation between initial implant stability quotient and bone-implant contact percentage: an in vitro model study. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013; 116(5): e356-361.
10.1016/j.oooo.2012.01.03722921444
25
Park KJ, Kwon JY, Kim SK, et al. The relationship between implant stability quotient values and implant insertion variables: a clinical study. J Oral Rehabil. 2012; 39: 151-159.
10.1111/j.1365-2842.2011.02255.x21923718
26
Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000. 2008; 47: 51-66.
10.1111/j.1600-0757.2008.00267.x18412573
27
Abdel-Haq J, Karabuda CZ, Arisan V, et al. Osseointegration and stability of a modified sand-blasted acid-etched implant: an experimental pilot study in sheep. Clin Oral Implants Res. 2011; 22: 265-274.
10.1111/j.1600-0501.2010.01990.x20946211
28
Blanco J, Alvarez E, Mu-oz F, et al. Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbit. Clin Oral Implants Res. 2011; 22: 92-99.
10.1111/j.1600-0501.2010.02009.x21039895
29
Antunes AA, Oliveira Neto P, De Santis E, et al. Comparisons between Bio-oss® and Straumann® bone ceramic in immediate and staged implant placement in dogs mandible bone defects. Clin Oral Implants Res. 2013; 24: 135-142.
10.1111/j.1600-0501.2011.02385.x22168758
30
Jun SH, Chang BM, Weber HP, et al. Comparison of initial stability parameters and histomorphometric analysis of implants inserted into extraction sockets: human fresh cadaver study. Int J Oral Maxillofac Implants. 2010; 25: 985-990.
20862413
31
Park IP, Kim SK, Lee SJ, et al. The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia. J Adv Prosthodont. 2011; 3: 76-80.
10.4047/jap.2011.3.2.7621814615PMC3141122
32
van Eekeren P, Said C, Tahmaseb A, et al. Resonance frequency analysis of thermal acid-etched, hydrophilic implants during first 3 months of healing and osseointegration in an early-loading protocol. Int J Oral Maxillofac Implants. 2015; 30; 843-850
10.11607/jomi.398526252037
33
Davies JE. Understanding peri-implant osseous healing. J Dent Educ. 2003; 67: 932-49.
12959168
34
Kim BS, Kim JS, Lee J. Improvements of osteoblast adhesion, proliferation, and differentiation in vitro via fibrin network formation in collagen sponge scaffold. Journal of Biomedical Materials Research Part A. 2013; 101: 2661-2666.
10.1002/jbm.a.3456723413086
35
Rai B, Oest ME, Dupont KM, et al. Combination of platelet-rich plasma with polycaprolactonetricalcium phosphate scaffolds for segmental bone defect repair. Journal of Biomedical Materials Research Part A. 2007; 81: 888-899.
10.1002/jbm.a.3114217236215
36
Aita H, Att W, Ueno T, et al. Ultraviolet light-mediated photofunctionalization of titanium to promote human mesenchymal stem cell migration, attachment, proliferation and differentiation. Acta Biomater. 2009; 5: 3247-3257.
10.1016/j.actbio.2009.04.02219427421
37
Jensen OT, Shulman LB, Block MS, et al. Report of the sinus consensus conference of 1996. Int J Oral Maxillofac Implants. 1998; 13(suppl): 11-32.
9715571
38
Lundgren S, Andersson S, Gualini F, et al. Bone reformation with sinus membrane elevation: a new surgical technique for maxillary sinus floor augmentation. Clin Implant Dent Relat Res. 2004; 6: 165-173.
10.1111/j.1708-8208.2004.tb00224.x15726851
39
Brägger U, Gerber C, Joss A, et al. Patterns of tissue remodelling after placement of ITIs dental implants using an osteotome technique: a longitudinal radiographic case cohort study. Clin Oral Implants Res. 2004; 15: 158-166.
10.1111/j.1600-0501.2004.00988.x15008927
40
Nedir R, Bischof M, Vazquez L, et al. Osteotome sinus floor elevation without grafting material: a 1-year prospective pilot study with ITI implants. Clin Oral Implants Res. 2006; 17: 679-686.
10.1111/j.1600-0501.2006.01264.x17092227
41
Kuchler U, Chappuis V, Bornstein MM, et al. Development of implant stability quotient values of implants placed with simultaneous sinus floor elevation - results of a prospective study with 109 implants. Clin Oral Implants Res. 2017; 28: 109-115.
10.1111/clr.1276826774074
42
Atsumi M, Park SH, Wang HL. Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants. 2007; 22: 743-754.
17974108
43
Valderrama P, Oates TW, Jones AA, et al. Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial. J Periodontol. 2007; 78: 262-272.
10.1902/jop.2007.06014317274715
44
Cho IH, Lee YI, Kim YM. A comparative study on the accuracy of the devices for measuring the implant stability. J Adv Prosthodont. 2009; 1: 124-128.
10.4047/jap.2009.1.3.12421165267PMC2994689
45
Nedir R, Bischof M, Szmukler-Moncler S, et al. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res. 2004; 15: 520-528.
10.1111/j.1600-0501.2004.01059.x15355393
46
Makary C, Rebaudi A, Sammartino G, et al. Implant primary stability determined by resonance frequency analysis: correlation with insertion torque, histologic bone volume, and torsional stability at 6 weeks. Implant Dent. 2012; 21: 474-480.
10.1097/ID.0b013e31826918f123149504
47
Sençimen M, Gülses A, Ozen J, et al. Early detection of alterations in the resonance frequency assessment of oral implant stability on various bone types: a clinical study. J Oral Implantol. 2011; 37: 411-419.
10.1563/AAID-JOI-D-09-0013020233069
48
Proceedings of the Third ITI (International Team for Implantology) Consensus Conference. Gstaad, Switzerland, August 2003. Int Oral Maxillofac Implants. 2004; 19(suppl): 7-154.
49
Berglundh T, Abrahamsson I, Lang NP, et al. De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res. 2003; 14: 251-262.
10.1034/j.1600-0501.2003.00972.x12755774
Information
  • Publisher :The Korean Academy of Oral & Maxillofacial Implantology
  • Publisher(Ko) :대한구강악안면임플란트학회
  • Journal Title :Implantology
  • Journal Title(Ko) :대한구강악안면임플란트학회지
  • Volume : 21
  • No :2
  • Pages :110-127
  • Received Date : 2017-06-02
  • Revised Date : 2017-06-09
  • Accepted Date : 2017-06-09