All Issue

2026 Vol.30, Issue 3

Original Article

30 September 2026. pp. 139-156
Abstract
References
1

Papavasiliou G, Kamposiora P, Bayne SC, Felton DA. Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. J Prosthet Dent 1996;76:633-40.

10.1016/S0022-3913(96)90442-4
2

Schmitt de Andrade G, Kalman L, Lo Giudice R, Adolfi D, Feilzer A, Tribst J. Biomechanics of implant-supported restorations. Braz Dent Sci 2023;26:e3637.

10.4322/bds.2023.e3637
3

Matta RE, Berger L, Loehlein M, Leven L, Taxis J, Wichmann M, et al. Stress distribution within the peri-implant bone for different implant materials obtained by digital image correlation. Materials 2024;17:2161.

10.3390/ma1709216138730967PMC11085640
4

Wang Q, Zhang ZZ, Bai SZ, Zhang SF. Biomechanical analysis of stress around the tilted implants with different cantilever lengths in all-on-4 concept. BMC Oral Health 2022;22:469.

10.1186/s12903-022-02520-836335327PMC9636816
5

Kim YK. Prosthesis-Implant Arch Area Ratio (PIAAR) - A new geometric paradigm, replacing the current “A-P Spread” of a cantilever in full-arch implant prosthesis: a proof-of-concept experiment. J Prosthodont Off J Am Coll Prosthodont 2023;32:227-33.

10.1111/jopr.13523
6

Clelland NL, Gilat A. The effect of abutment angulation on stress transfer for an implant. J Prosthodont Off J Am Coll Prosthodont 1992;1:24-8.

10.1111/j.1532-849X.1992.tb00422.x
7

Himmlová L, Dostálová T, Kácovský A, Konvicková S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent 2004;91:20-5.

10.1016/j.prosdent.2003.08.008
8

Manchikalapudi G, Basapogu S. Finite Element Analysis of effect of cusp inclination and occlusal contacts in PFM and PEEK implant-supported crowns on resultant stresses. Med J Armed Forces India 2022;78:80-7.

10.1016/j.mjafi.2020.11.01435035048PMC8737102
9

D’haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computer-guided implant surgery. Periodontol 2000 2017;73:121-33.

10.1111/prd.12175
10

Falcinelli C, Valente F, Vasta M, Traini T. Finite element analysis in implant dentistry: state of the art and future directions. Dent Mater 2023;39:539-56.

10.1016/j.dental.2023.04.002
11

Assaf M, Abu Gharbyeh AZ. Screw-retained crown restorations of single implants: a step-by-step clinical guide. Eur J Dent 2014;8:563-70.

10.4103/1305-7456.14364525512742PMC4253117
12

Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol 1998;24:80-8.

10.1563/1548-1336(1998)024<0080:EPOODI>2.3.CO;2
13

Ferrario VF, Sforza C, Serrao G, Dellavia C, Tartaglia GM. Single tooth bite forces in healthy young adults. J Oral Rehabil 2004;31:18-22.

10.1046/j.0305-182X.2003.01179.x
14

Isidor F. Influence of forces on peri-implant bone. Clin Oral Implants Res 2006;17 Suppl 2:8-18.

10.1111/j.1600-0501.2006.01360.x
15

Haseeb SA, Kumar AS, Chaitra MP, Vinaya KC, Gudal SS, Rahmam FP, et al. Finite element analysis to assess stress and deformation in bone with glass fiber-reinforced-poly-ether-ether-ketone, zirconia, and titanium implants. Tzu Chi Med J 2023;35:231-6.

10.4103/tcmj.tcmj_184_2237545794PMC10399843
16

Di Fiore A, Montagner M, Sivolella S, Stellini E, Yilmaz B, Brunello G. Peri-implant bone loss and overload: a systematic review focusing on occlusal analysis through digital and analogic methods. J Clin Med 2022;11:4812.

10.3390/jcm1116481236013048PMC9409652
17

Goellner M, Schmitt J, Karl M, Wichmann M, Holst S. The effect of axial and oblique loading on the micromovement of dental implants. Int J Oral Maxillofac Implants 2011;26:257-64.

18

Didier P, Piotrowski B, Le Coz G, Joseph D, Bravetti P, Laheurte P. Finite element analysis of the stress field in peri-implant bone: a parametric study of influencing parameters and their interactions for multi-objective optimization. Appl Sci 2020;10:5973.

10.3390/app10175973
19

Misch CE, Bidez MW, Sharawy M. A bioengineered implant for a predetermined bone cellular response to loading forces. A literature review and case report. J Periodontol 2001;72:1276-86.

10.1902/jop.2000.72.9.1276
20

De Boever JA, McCall WD, Holden S, Ash MM. Functional occlusal forces: an investigation by telemetry. J Prosthet Dent 1978;40:326-33.

10.1016/0022-3913(78)90042-2
21

Baggi L, Cappelloni I, Di Girolamo M, Maceri F, Vairo G. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis. J Prosthet Dent 2008;100:422-31.

10.1016/S0022-3913(08)60259-0
22

Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 2001;85:585-98.

10.1067/mpr.2001.115251
23

Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 1981;52:155-70.

10.3109/17453678108991776
24

Ash MM, Ramfjord SP. Occlusion. 4th ed. Philadelphia: W.B. Saunders; 1995. p. 87-93.

25

Rangert B, Krogh PH, Langer B, Van Roekel N. Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1995;10:326-34.

26

Rangert B, Jemt T, Jörneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989;4:241-7.

27

Gere JM, Timoshenko S. Mechanics of materials. 3rd ed. Boston: PWS-Kent Pub. Co; 1990.

10.1007/978-1-4899-3124-5
28

Gordon JE. Structures, or, Why things don’t fall down. 2nd Da Capo Press ed. New York: Da Capo Press; 2003.

29

Sevimay M, Turhan F, Kiliçarslan MA, Eskitascioglu G. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown. J Prosthet Dent 2005;93:227-34.

10.1016/j.prosdent.2004.12.019
30

Alzahrani KM. Implant bio-mechanics for successful implant therapy: a systematic review. J Int Soc Prev Community Dent 2020;10:700-14.

10.4103/jispcd.JISPCD_138_2033437702PMC7791586
31

Frost HM. Bone’s mechanostat: a 2003 update. Anat Rec A Discov Mol Cell Evol Biol 2003;275:1081-101.

10.1002/ar.a.10119
32

Akça K, Iplikçioğlu H. Finite element stress analysis of the influence of staggered versus straight placement of dental implants. Int J Oral Maxillofac Implants 2001;16:722-30.

33

Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 2014;29:25-42.

10.11607/jomi.2014suppl.g1.2
34

Derks J, Tomasi C. Peri-implant health and disease. A systematic review of current epidemiology. J Clin Periodontol 2015;42 Suppl 16:S158-71.

10.1111/jcpe.12334
35

Kul E, Korkmaz İH. Effect of different design of abutment and implant on stress distribution in 2 implants and peripheral bone: a finite element analysis study. J Prosthet Dent 2021;126:664.e1-e9.

10.1016/j.prosdent.2020.09.058
36

Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JYK. Clinical complications with implants and implant prostheses. J Prosthet Dent 2003;90:121-32.

10.1016/S0022-3913(03)00212-9
37

O'Mahony AM, Williams JL, Spencer P. Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading. Clin Oral Implants Res 2001;12:648-57.

10.1034/j.1600-0501.2001.120614.x
38

Iyo T, Maki Y, Sasaki N, Nakata M. Anisotropic viscoelastic properties of cortical bone. J Biomech 2004;37:1433-7.

10.1016/j.jbiomech.2003.12.023
39

Shunmugasamy VC, Gupta N, Pessoa RS, Janal MN, Coelho PG. Influence of clinically relevant factors on the immediate biomechanical surrounding for a series of dental implant designs. J Biomech Eng 2011;133:031005.

10.1115/1.4003318
40

Gasparro R, Renno F, De Vita S, Lanzotti A, Martorelli M, Penta F, et al. Loading pressure induced by 4 mm implants on the inferior alveolar nerve: a 3D finite element analysis model. J Clin Med 2025;14:2535.

10.3390/jcm1407253540217984PMC11989299
Information
  • Publisher :The Korean Academy of Oral & Maxillofacial Implantology
  • Publisher(Ko) :대한구강악안면임플란트학회
  • Journal Title :Journal of implantology and applied sciences
  • Journal Title(Ko) :대한구강악안면임플란트학회지
  • Volume : 30
  • No :3
  • Pages :139-156
  • Received Date : 2026-06-18
  • Revised Date : 2026-08-23
  • Accepted Date : 2026-08-28