All Issue

2024 Vol.28, Issue 3 Preview Page

Clinical or Case Report

30 September 2024. pp. 142-150
Abstract
References
1

Wittneben JG, Buser D, Salvi GE, Bürgin W, Hicklin S, Brägger U. Complication and failure rates with implant-supported fixed dental prostheses and single crowns: A 10-year retrospective study. Clin Implant Dent Relat Res 2014;16:356-64.

10.1111/cid.12066
2

Nergiz I, Schmage P, Shahin R. Removal of a fractured implant abutment screw: A clinical report. J Prosthet Dent 2004;91:513-17.

10.1016/j.prosdent.2004.03.010
3

Zhang WT, Ding YD, Wang LH, Yang F. Retrieval of a fractured implant abutment using a modified cover screw removal instrument: A clinical report. J Prosthet Dent 2023;15:S0022-3913(23)00543-7.

10.1016/j.prosdent.2023.07.038
4

Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implants Res 2008;19:119-30.

10.1111/j.1600-0501.2007.01453.x
5

Goodacre CJ, Kan JYK, Rungcharassaeng KR. Clinical complications of osseointegrated implants. J Prosthet Dent 1999;81:537-52.

10.1016/S0022-3913(99)70208-8
6

Mizumoto RM, Jamjoom FZ, Yilmaz B. A risk-based decision making tree for managing fractured abutment and prosthetic screws: A systematic review. J Prosthet Dent 2018;119:552-59.

10.1016/j.prosdent.2017.05.016
7

Chowdhary R, Sonnahalli NK, Gala JN. Implant abutment screw fracture and techniques of retrieval: a literature review based on a novel abutment screw fracture classification. J Osseointegr 2023;15:32-9.

10.23805/JO.2023.15.01.06
8

Taira Y, Sawase T. A modified technique for removing a failed abutment screw from an implant with a custom guide tube. J Oral Implantol 2012;38:165-69.

10.1563/AAID-JOI-D-10-00162
9

Yoon JH, Lee H, Kim MY. Safe Removal of a Broken Abutment Screw with Customized Drill Guide and Rotary Instrument: A Clinical Report. J Prosthodont 2016;25:170-3.

10.1111/jopr.12291
10

Huang H, Zhang Z, Lin P, Xiang Y, Xu Y, Chen Y, et al. Removal of broken screws on implant abutment by digital guide plate: A case report and literature review. J Appl Biomater Funct Mater 2023;21:1-2.

10.1177/22808000231186226
Information
  • Publisher :The Korean Academy of Oral & Maxillofacial Implantology
  • Publisher(Ko) :대한구강악안면임플란트학회
  • Journal Title :Journal of implantology and applied sciences
  • Journal Title(Ko) :대한구강악안면임플란트학회지
  • Volume : 28
  • No :3
  • Pages :142-150
  • Received Date : 2024-09-13
  • Revised Date : 2024-09-20
  • Accepted Date : 2024-09-24